A green method was established for the mutual determination of the drug trifluoperazine hydrochloride (TFPH) and vanadium (V) in real samples by coupling the cloud point extraction with UVVis spectrophotometry. The method was based on the formation of the colored V (V)TFPH complex in acidic medium followed the extraction of the complex by using the surfactant Triton X114 as an extracting ...
Thallium is either extracted from the dusts from the smelter flues or from residues such as slag that are collected at the end of the smelting process.[20] The raw materials used for thallium production contain large amounts of other materials and therefore a purification is the first step. The thallium is leached either by the use of a base or ...
ETAAS procedures for anal. of biol. tissues and urine have been elaborated. Simple techniques for preinstrumental treatment and fast temp. programs are expedited. Applications to different biol. ref. materials have been demonstrated. The relative errors and RSDs are less than 10%, and the analyte recoveries are within 96 and 108%.
This International Standard specifies methods for extraction of thallium from soil by nitric acid and hydrogen peroxide and its determination in the extract by electrothermal atomic absorption spectrometry (ETAAS). NOTE The relevant working range of this method is approximately from 0,05 mg/kg to .
determination of thallium in geological samples by electrothermal atomic absorption spectrometry more by Trajce Stafilov Thallium is a rare element, present in the earth crust below 1 ppm.
Separation of Tl(I) and Tl(III) from Environmental Water Samples by Flotation Method Coupled with Zeeman ETAAS Determination Jozica Majda Bundalevska,1 Ikbal Koyuncu,2 Umit Ay,¨ 3 Katarina Cundeva,ˇ 1 G¨oksel Ak¸cin,2 and Trajˇce Stafilov1 1Institute of Chemistry, Faculty of Science, Sts. Cyril and Methodius University, Macedonia
Thermal stabilization of several volatile elements (antimony, arsenic, bismuth, cadmium, lead, selenium, tin, and thallium) in biol. digests, solubilized hair and dild. urine in the presence of mixed modifiers: palladiumtungsten and palladiumtungstenammonium nitrate (for urine) has been studied. ETAAS procedures for anal. of biol. tissues and urine have been elaborated.
Abstract A fast method for separation of Cd, Cu, Fe, Ni, Pb, Zn, and Tl from seawater before their determination by atomic absorption spectrometry (AAS) is described. The ability of Co(III) hexamethylenedithiocarbamate, Co(HMDTC)3, as a flotation collector for metals from seawater was investigated. The influence of pH of the media, as one of the crucial parameters for effective flotation, .
EPA IO [Inorganic] Compendium Method : Determination of Metals in Ambient Particulate Matter Using Inductively Coupled Plasma/Mass Spectrometry (ICPMS) This document is included in Selected Analytical Methods for Environmental Remediation and Recovery (SAM) .
"Ionic liquids and biological substrates as green alternatives for the preconcentration and determination of elemental microcontaminants" L. B. Escudero (oral presentation with the sponsorship of OPCW)
Determination of thallium in bovine liver and mouse brains by laser excited atomic fluorescence spectrometry in a graphite tube furnace Joseph P. Dougherty, Julie A. Costello, and Robert G. Michel
(ETAAS) was employed for determination of thallium in aqueous solution. The limit of detection for the method
" Electrothermal atomic absorption spectrometric determination of trace elements in highpurity silver after total and partial reductive separation of the matrix ". J. Cvetcovich, S. Arpadjan, I. Karadjova, T. Stafilov. "Determination of thallium in wines after extraction preconcentration" Spectrochim.
thallium compounds in air for 720L air sample. The average value of mineralization was The developed method for the determination of thallium and its compounds enables determination of minimum amount of thallium and its compounds in workplace air at mg/m. 3. This method is accurate, precise and it meets the
ETAAS method is 50 (elution of the sorbed Tldithiocarbamate complex with mL of IBMK). It was registered that for more contaminated water samples with heavy metals concentration at the mg L1 level the sorption of thallium is quantitative for water sample solution volumes up to 100 mL.
Provides methods for extraction of thallium from soil by nitric acid and hydrogen peroxide and its determination in the extract by electrothermal atomic absorption spectrometry (ETAAS).
trapping for determination of low concentrations of selenium by ETAAS, 14 we have found that detection limits are governed by impurities in the borohydride reagent. We considered that the immobilization of borohydride on an anionexchange resin might result in a purer .
The partial pressure of thallium in highpressure HgTlI discharges with different mercury, thallium, and electron pressures has been measured by using the optically thin line Tl 655 nm and the selfreversed line Tl 535 nm. The partial pressure of the arc axis has been measured from the line Tl 655nm.
ETAAS determination of thallium and silver from water matrix after colloidal precipitate flotation using lead (II) hexamethylenedithiocarbamate
This International Standard specifies methods for extraction of thallium from soil by nitric acid and hydrogen peroxide and its determination in the extract by electrothermal atomic absorption spectrometry (ETAAS). NOTE The relevant working range of this method is approximately from 0,05 mg/kg to 100 mg/kg. 2 Normative references
Two preconcentration procedures for electrothermal atomic absorption (ETAAS) determination of thallium in mineral, spring, tap, river, underground and sea water were developed and compared: (i) Column solid phase extraction with new sandwich type disposable sorbent columns (CSPE) and (ii) Filtration of thallium dithiocarbamates through a Millipore filter of mm pore size followed by .
IS 26001: Methods of chemical analysis of zinc and zinc base alloys for die castings, Part 1: Determination of copper, iron, nickel, tin and thallium by spectrophotometric method Item Preview removecircle Share or Embed This Item.
are observed using ETAAS for thallium determination. Due to a high chloride concentration in aqua regia extracts, thallium will be volatilised and lost during the pretreatment step. Therefore, in this International Standard, a mixture of nitric acid and hydrogen peroxide will .
, 9/10/96 1:41 PM Safety Information The Analytical Methods section describes methodologies using a wide variety of potentially hazardous chemicals (acids, bases, organic